PD in byte 5
Warnings Low-Byte
PD in byte 6
Vacuum High-Byte
PD in byte 7
Vacuum Low-Byte
PD in byte 8
Reserved
PD in byte 9
Reserved
PD in byte 10
Reserved
PD in byte 11
Reserved
PD in byte 12
Reserved
PD in byte 13
Reserved
PD in byte 14
Reserved
PD in byte 15
Reserved
Process data Out
Vacuum
Blow-off
Setting Mode
PD out byte 0
CM-Autoset
Reserved
PD out byte 1
Input Pressure
PD out byte 2
Reserved
Profile Set
PD out byte 3
Reserved
ISDU Parameters
ISDU Index
Subindex
dec
hex
dec
Identification
Device Management
16
0x0010
0
Vendor name
17
0x0011
0
Vendor text
18
0x0012
0
Product name
19
0x0013
0
Product ID
20
0x0014
0
Product text
21
0x0015
0
Serial number
22
0x0016
0
Hardware revision
23
0x0017
0
Firmware revision
240
0x00F0
0
Unique device identification
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
0..7
Bits
0
1
2
3
4..7
0..7
0..7
0..1
2..7
Parameter
Size
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
9
bytes
2
bytes
4
bytes
9
bytes
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
ro
Bit 4 = Free Flow Vacuum over SP2
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
ro
System vacuum [mbar]
ro
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
ro
not used
Access
Remark
wo
Vacuum on/off
wo
Activate Blow-off
Vacuum on/off with continuous suction disabled
wo
(regardless of dCS parameter)
Perform CM Autoset function (teach permissible leakage and
wo
permissible evacuation time)
wo
not used
wo
Pressure value from external sensor [0.1 bar]
wo
not used
wo
Profile selection
wo
not used
Value
Access
Default Value
Range
-
ro
J. Schmalz GmbH
-
ro
Innovative Vacuum Solutions Internet address
-
ro
RECB_MATCH_1C
-
ro
'RECB_MATCH_1C
-
ro
RECB 24V-DC MATCH 1-C Order-code
-
ro
000000001
-
ro
-
ro
-
ro
Remark
Manufacturer designation
Product name
Product variant name
Serial number
00
Hardware revision
1.0
Firmware revision
-
Unique ID