Descargar Imprimir esta página

schmalz RECB 24V CC NC MATCH-PXT1 1C Manual De Instrucciones página 78

Publicidad

Resetpoint 2 (rP2)
103
0x0067
0
106
0x006A
0
Duration automatic blow
107
0x006B
0
Permissable evacuation time
Permissable leakage rate
108
0x006C
0
119
0x0077
0
Profile name
Production Setup - Profile P1
180
0x00B4
0
Air-Saving function
181
0x00B5
0
Disable continous sucking
Switchpoint 1 (SP1)
182
0x00B6
0
183
0x00B7
0
Resetpoint 1 (rp1)
184
0x00B8
0
Switchpoint 2 (SP2)
Resetpoint 2 (rp2)
185
0x00B9
0
186
0x00BA
0
Duration automatic blow
187
0x00BB
0
Permissable evacuation time
Permissable leakage rate
188
0x00BC
0
199
0x00C7
0
Profile name
Production Setup - Profile P2
200
0x00C8
0
Air-Saving function
201
0x00C9
0
Disable continous sucking
202
0x00CA
0
Switchpoint 1 (SP1)
203
0x00CB
0
Resetpoint 1 (rp1)
204
0x00CC
0
Switchpoint 2 (SP2)
Resetpoint 2 (rp2)
205
0x00CD
0
206
0x00CE
0
Duration automatic blow
207
0x00CF
0
Permissable evacuation time
Permissable leakage rate
208
0x00D0
0
219
0x00DB
0
Profile name
Production Setup - Profile P3
220
0x00DC
0
Air-Saving function
221
0x00DD
0
Disable continous sucking
Switchpoint 1 (SP1)
222
0x00DE
0
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1 >
2
bytes
rw
SP2
rP1 > SP2 >
2
bytes
rw
rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1 >
2
bytes
rw
SP2
rP1 > SP2 >
2
bytes
rw
rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms
2000
no evacuation time warning if set to 0
Unit: 1mbar/s
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1ms,
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1ms,
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off
0
1 = on
750
Unit: 1mbar