Descargar Imprimir esta página

Johnson AEROTERMIA AURUM R32 Serie Manual De Instrucciones página 107

Publicidad

Idiomas disponibles

Idiomas disponibles

Power Cable And Signal Wire Connection Instruction
1. Remove the machine's front cover and connect the wire to the corresponding terminal block
according to the electrical wiring diagram to confirm that the connection is secure.
2. Secure the cable with the wire clamp and install the service plate.
3. Do not connect the wrong line. Otherwise, it will cause electrical failure or even damage the
machine.
4. The type and rating of the fuse are based on the specifications of the corresponding controller or
fuse cover.
5. The power cable must be selected and installed by a professional installer. When the installer
chooses the power cable, the power cable should not be lighter than the neoprene armoured cord
(line 57 of IEC 60245). For specific power cable specifications, see the electrical specifications.
6. If the user's power distribution capacity is insufficient or the power cord (copper core wire) is not
configured as required, the machine cannot be started or operated normally. The seller will not
take any responsibility.
Motherboard Output Definitions
40
V.1

Publicidad

loading

Este manual también es adecuado para:

Aerotermia aurum80mAerotermia aurum100mAerotermia aurum160m