Tools for installation
1 Level meter
4 Drill head
7 Open-end wrench
10 Vacuum pump
13 Inner hexagon spanner
Note:
● Please contact the local agent for installation.
● Don't use unqualified power cord.
Selection of installation location
Basic requirements
Installing the unit in the following pla-
ces may cause malfunction. If it is u-
navoidable, please consult the local
dealer:
1. The place near strong heat sources
vapors, flammable or explosive gas,
or volatile objects spread in the air.
2. The place with high-frequency dev-
ices (such as welding machine,
medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circums-
tances.
7. Please try your best to keep way
from fluorescent lamp.
Outdoor unit
1. Select a location where the noise and outflow air emitted by the outdoor unit
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit won't
be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimen-
sion diagram.
5. Select a location which is out of reach for children and far away from animals
or plants. If it is unavoidable, please add fence for safety purpose.
6. The height difference between indoor unit and outdoor unit should be within
5m. The length of connection pipe should be within 10m.
2 Screw driver
5 Pipe expander
8 Pipe cutter
11 Pressure meter
Indoor unit
1. Avoid installing the indoor unit in a place
where generated or leaked inflammable
gas will stay.
2. Avoid installing the indoor unit in a moist
place or in a place where oil may be
splashed on the unit.
3. Select a location where outlet air may
reach each corner of the room.
4. Select a location where connection pipe
can be led to outdoor conveniently.
5. Select a location where air inlet and
outlet won't be blocked.
6. Select a location with least affection of
outdoor air.
7. Select a location with firm and flat floor.
8. Retain sufficient space for maintenance
and installation.
9. Ensure the installation meets the requir-
ement of installation dimension diagram.
10. Do not use the unit in the immediate
surroundings of a laundry a bath a
shower or a swimming pool.
26
3 Impact drill
6 Torque wrench
9 Leakage detector
12 Universal meter
14 Measuring tape