Descargar Imprimir esta página

HTW -FST3-O-160A9 Manual De Usuario E Instalacion página 34

Columna de aire acondicionado

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation of outdoor unit
Step one: fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
● Take sufficient protective measures when
installing the outdoor unit.
● Make sure the support can withstand at
least four times the unit weight.
● The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
● For the unit with cooling capacity of 2300W~
5000W, 6 expansion screws are needed; for
the unit with cooling capacity of 6000W~
8000W, 8 expansion screws are needed;
for the unit with cooling capacity of
10000W~16000W, 10 expansion screws
are needed.
Step two: install drain joint
(only for cooling and heating
unit)
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
drain vent
drain hose
2. Connect the drain hose into the drain
vent.
chassis
outdoor drain joint
at least 3cm above the floor
Step three: fix outdoor unit
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
32
foot holes
foot holes

Publicidad

loading