Installation of indoor unit
2. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
and then fix the power connection wire
with wire clip.
brown
3. Adjust the position of upper and lower
adjusting baffle; clamp the connection
pipe and drain pipe as firm as possible.
Step seven: bind up pipe
1. Bind up the connection pipe, power cord
and drain hose with the band.
indoor unit
gas pipe
2. Reserve a certain length of drain hose
and power cord for installation when
binding them. When binding to a certain
degree, separate the indoor power and
then separate the drain hose.
connection pipe
indoor power cord
L1 L2 L3
N
black vioet
blue
yellow-
green
Outdoor unit connection
indoor and outdoor power cord
band
drain hose
drain hose
4. Tighten the screws.
All wires of indoor unit and outdoor
unit should be connected by a pr-
ofessional.
● If the length of power connection
● For the air conditioner with plug,
● For the air conditioner without
3. Wrap it evenly, and rolling width
should be 1/3 of bandaging belt.
Do not wrap it too tight or too loose.
4. The liquid pipe and gas pipe sho-
uld be bound separately at the end.
liquid pipe
band
30
Note:
wire is insufficient, please conta-
ct the supplier for a new one. Avo-
id extending the wire by yourself.
the plug should be reachable
after finishing installation.
plug, an air switch must be inst-
alled in the line. The air switch
should be all-pole parting and the
contact parting distance should
be more than 3mm.
Note:
The power cord and control wire
can't be crossed or winding.
The drain hose should be bound at
the bottom.