In the drop-down menu, click on the "Devices" button.
The "Devices" panel will appear. The devices assigned to the
plant will appear in this panel.
To add the device (485/WiFi EQX2) communication module to the
plant, press the "add" button
Next, select the 485/WiFi EQX2 device to start the pairing
process.
96
[ + ]
to the right of "Devices".
The WiFi dongle comes from the factory with the Bluetooth
configuration. It must be changed to WiFi.
The pairing process has 3 steps:
Connect the dongle:
1.
Make sure that the dongle is plugged into the unit's
a.
USB port.
Press the "Next" button.
b.
Add device.
2.
You must link the inverter's serial number to add the unit to
the plant.
Press the "Scan" button.
a.
The smartphone or tablet may request permis-
sion to use the camera. Permission is required.
Move the camera closer to the barcode that appears
b.
on the inverter label. When the code is detected,
the scanner will close and the serial number will be
written automatically.
Check that the serial number corresponds to the one on
the label.
Fig. 68. Example of a barcode identification label.
SALICRU