Each plant has four tabs at the top:
"Alarms" and "Info".
Information shown in the
1.
This tab is divided into 5 sections: Synoptic, Generation,
Consumption,
Battery charging
generation.
USER MANUAL
"Real time", "Historical",
"Real Time"
tab:
Daily savings by
and
The synoptic chart offers a very visual approximation of the
current state of the plant: the movement of the lines indi-
cates the direction of energy flow, and its colour indicates
whether it comes from the grid (red), from the panels (green),
or from the battery (yellow). The colour of the consumption
load line is always red. In this example of a  commercial
installation with an installed power of 6 kWp, 2.97 kW of
back-up and 874 W of on-grid loads are being consumed.
We  have 2.21  kW of self-consumption from photovoltaic
generation, 1.62 kW of self-consumption from batteries and
the remaining 16 W from the grid.
In the following example of the same commercial installation,
975 W of back-up loads and 856 W of on-grid load are being
consumed, which are powered by the 2.15 kW of photovol-
taic generation, the surpluses are directed to charging the
battery (-340 W, negative indicates charging).
The Generation section shows the "Today", "Current month"
and "Total" data (since the plant was registered). The infor-
mation has the same format in all tabs. In this example,
5.3 MWh have been generated today, of which 4.8 MWh
have been self-consumed, while the remaining 500 kWh
have been exported or injected into the grid.
The "Consumption" section shows the "Today", "Current
month" and "Total" data (since the plant was registered).
The  information has the same format in all tabs. In this
example, of today's total consumption (100%), 4.8 kWh
(94.12%) have been self-consumed while 300 Wh (5.88%)
have been imported from the grid.
The "Battery Charging" section shows the "Today", "Current
month" and "Total" data (since the plant was registered).
The  information has the same format in all tabs. In this
example, today's total battery charge is 1 kW and 100%
charged from the solar panels.
The "Daily savings by generation" section shows an estimate
of the savings obtained by self-consumption, the  amount
resulting from multiplying the self-consumed energy by the
amount of compensation per kWh injected into the grid.
EQX2 SOLAR INVERTERS CONNECTED TO THE GRID
99