1. Heating element power
230V: 28.5-29.7, 240V: 30.9-32.2 ohm
2. Visual heating element inspection.
3. Line voltage.
4. Levelling of the machine.
5. Drain installation.
6. Water supply.
7. Leakage at drain and inlet valve.
8. Calibration of water level scale.
Document number:
Mandatory Measured After
R1 ohm
R2 ohm
R3 ohm
Visual
OK
L1-L2
L1-L3
L2-L3
lf-lr
< 5 mm
rf-rr
< 5 mm
lf-rf
< 5 mm
lr-rr
< 5 mm
d (mm)
> 50 mm
P (bar)
2-6 bar
Filltime
60-75 sec
0 ± 1 mm
Leakage
Level
0-200 mm
page 2 (3)
adjust