3.5
Manually Terminating the Calibration Process
When and where to use: Calibration may be terminated at any time during the calibration process of
the battery (steady amber).
Procedure:
1 Remove the battery from the charger pocket.
2 Within five seconds, reinsert the battery into the charger pocket.
The charger terminates the calibration process and begins the charging process. The charger
indicator changes to a steady red. The charger attempts to calibrate the battery at the next
battery insertion.
3.6
Manually Initiating the Calibration Process
Procedure:
1 Insert the battery into the charger pocket.
2 Within 2.5 minutes, remove the battery from the charger pocket.
3 Within five seconds, reinsert the battery into the charger pocket.
The charger indicator changes from steady red to steady amber. The charger is forced to
calibrate and automatically recharge the battery. Two or three manual calibration cycles may be
required to recharge the batteries due to long-term storage conditions.
3.7
IMPRES 2 or IMPRES End-of-Service-Life LED Indication
The charger may indicate IMPRES 2 or IMPRES battery End-of-Service by alternating Red and Green
LED upon successful completion of calibration or reconditioning.
When batteries are used, normal wear reduces available capacity. At the successful completion of
calibration or reconditioning, IMPRES chargers compare IMPRES 2 or IMPRES battery capacity to the
battery rated capacity. When the capacity is at a very low value, the IMPRES 2 or IMPRES battery may
be nearing its end of service. The IMPRES 2 or IMPRES battery remains usable. In some scenarios,
it may be preferable to deploy the battery to someone who does not require large battery capacity to
complete a work shift.
APX NEXT XN battery comes with high temperature detection feature that is detectable from IMPRES
2 charger with software version V2.02 or newer. When this feature is enabled, the status LED
flashes Red and Green alternately upon charge completion for battery that went through prolonged
exposure (exceeding 10 minutes cumulatively) under extreme high temperature environment. The
charger displays the following:
REPLACE BATTERY
EXPOSED OVERTEMP
It is recommended to remove this battery out from the service.