Programming Parameters - Beretta EXCLUSIVE GREEN HE C.S.I. Serie Manual Del Instalador Y Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
2) Viewing just the
symbol (Fig. C)
Press the
button to reset the appliance. If the boiler starts the ignition
phase and resumes normal operation, it may have stopped by accident.
If these stoppages should continue, contact the Technical Assistance Centre.
3) Viewing the
and
symbols (Fig. D)
Contact the Technical Assistance Centre.
Note (C.S.I.)
Fault in domestic hot water circuit sensor - 60: the boiler works regularly but
does not ensure the stability of the hot water temperature which, however,
is delivered at a temperature of approximately 50°C. The fault code is only
displayed in standby.

15 - PROGRAMMING PARAMETERS

This boiler incorporates a new generation of electronic boards that, by setting/
modifying operating parameters, allow the boiler to be personalised to satisfy
various system and/or user requirements. The programmable parameters are
shown in the table on the next page.
The parameters must be programmed with the boiler in the OFF position.
To do this, press the
button until the display shows "- -" (Fig. E).
During parameter modifi cation operations, the "select functions" button
acts as an ENTER (confi rm) button, the
(escape) button. If no confi rmation is given within 10 seconds, the value
is discarded and returns to the previously set one.
B
Temporary
fault
Permanent
fault
C
D
Setting the password
Press and hold down the select functions button and the
for about 10 seconds. The display will look like Fig. F. Enter the password for
accessing the parameter modifi cations function by turning the domestic hot
water temperature selector to obtain the required value. The password for
accessing the parameter programming function is located on the back side
of the control panel. Confi rm by pressing ENTER.
Modifying parameters
Turn the domestic hot water temperature selector (Fig. G) to sequentially
scroll the two-fi gure codes of the parameters indicated in the table. After
identifying the parameter you wish to modify, proceed as follows:
- press ENTER to access the parameter modifi cation function. When ENTER
- turn the domestic hot water temperature selector to change the value
- press ENTER to confi rm the new value. The digits stop fl ashing
- press ESCAPE to exit.
The boiler returns to the "- -" (OFF) status.
To reset, press the
button acts as an ESCAPE
is pressed, the previously set value starts fl ashing (Fig.H)
button (Fig. E).
E
F
G
H
ENGLISH
button together
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exclusive green he r.s.i. serieExclusive green he 25 c.s.i.Exclusive green he 35 c.s.i.Exclusive green he 25 r.s.i.Exclusive green he 35 r.s.i.