Serial Number Plate - Beretta EXCLUSIVE GREEN HE C.S.I. Serie Manual Del Instalador Y Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Thermoregulation curves
100
90
80
70
60
50
40
30
20
20
15
10
EXTERNAL TEMPERATURE (°C)
P21 = MAXIMUM HEATING SET POINT
P22 = MINIMUM HEATING SET POINT
Parallel night reduction
90
DAY
80
temperature curve
70
60
50
40
30
20
10
20
15
10
EXTERNAL TEMPERATURE (°C)

17 - SERIAL NUMBER PLATE

DHW operation
CH operation
Qn
nominal capacity
Pn
nominal power
IP
protection level
P. min
minimum pressure
Pmw
DHW maximum pressure
Pms
CH maximum pressure
T
temperature
working effi ciency
D
specifi c capacity
NOx
NOx value class
Via Risorgimento 13 - 23900 Lecco (LC) Italy
Condensing boiler
230 V ~ 50 Hz
Serial N.
European Directive
NOx:
ç
92/42/ EEC:
=
IPX5D
Pmw = 6 bar T= 60 °C
Pms = 3 bar T= 90 °C
GRAPH 1
37,5
32,5
40
35
30
27,5
25
22,5
5
0
-5
-10
-15
GRAPH 3
NIGHT
temperature curve
5
0
-5
-10
-15
Gas type:
Gas category:
Qn
Qm
80-60 °C
80-60 °C
Qn (Hi) =
Pn =
set at:
D:
l/min
dostosowane do:
20
90
80
17,5
70
15
P.21
12,5
60
10
50
7,5
40
5
30
+5˚C
2,5
20
P.22
0˚C
10
-20
30
25
18 - ADJUSTMENTS
The boiler has already been factory adjusted by the manufacturer. If a new
adjustment is required, for example, after extraordinary maintenance, repla-
cing the gas valve or converting from natural gas to LPG, proceed as follows.
Maximum and minimum power, minimum and maximum heating,
must be adjusted in the indicated sequence by qualifi ed staff.
- Unscrew the lower cover fi xing screw (C, Fig. 1.4)
- Pull the cover towards you and remove (A-B) (Fig. 1.5)
- Loosen the two fi xing screws (D) and remove the shell (Fig. 1.2)
- Lift up the panel and turn it forwards
- Loosen the pressure tap screw downline from the gas valve by about two
turns and connect the pressure gauge to it
CALIBRATION & SERVICE operations must be performed with the boiler
in the OFF position. To do this, press the
"- -" (Fig. E).
During parameter modifi cation operations, the "select functions" button
acts as an ENTER (confi rm) button, the
button. If no confi rmation is given within 10 seconds, the value is discar-
ded and returns to the previously set one.
-20
Setting the password
Press and hold down the operating mode button and the
for about 10 seconds. The display will look like Fig. F.
Enter the password for accessing the parameter modifi cations function by
turning the domestic hot water temperature selector to the required value.
The password is located on the back side of the control panel. Confi rm by
pressing ENTER.
Calibration phases
Turn the domestic hot water selector to sequentially scroll the CALIBRATION
& SERVICE phases:
1
gas type (don't modify this parameter)
2
boiler power (minor parameter)
3
insulation level of building (only if external sensor is connected)
10 domestic hot water mode (Exclusive Green HE CSI: do not modify this
parameter)
45 inclination of thermoregulation curve (OTC), only if external sensor is
connected)
47 inclination of thermoregulation curve 2CH (OTC), only if external sensor
is connected)
HP maximum fan speed (do not modify this parameter)
LP minimum fan speed (do not modify this parameter)
SP ignition speed (do not modify this parameter)
HH boiler at maximum power
LL boiler at minimum power
MM fan ignition speed (do not modify this parameter)
23 maximum heating adjustment possibility (do not modify this parameter)
24 minimum heating adjustment possibility (do not modify this parameter).
The parameters 10 - HP - SP - LP - MM - 23 - 24 must be modifi ed,
by professionally qualifi ed personnel, only if absolutely necessary.
The manufacturer refuses any responsibility in the case of incorrect
setting of the parameters.
MAXIMUM VENTILATOR SPEED (P. HP)
- Select parameter HP
Qn
- Press the ENTER button, then modify the value of the parameter by turning
50-30 °C
the sanitary water temperature selector. The maximum speed of the fan is
linked with the type of gas and the power of the boiler, table 1
- Turn the sanitary water temperature selector in order to adjust the set value
- Confi rm the new value you have set by pressing ENTER.
The value indicated on the display is expressed in revs min/100 (example
3600 = 36).
The value set during this operation automatically modifi es the maximum
value of parameter 23.
GRAPH 2
Temperature curve correction
-5˚C
20
15
10
5
0
-5
EXTERNAL TEMPERATURE (°C)
button until the display shows
button acts as an ESCAPE
ENGLISH
-10
-15
-20
button together
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exclusive green he r.s.i. serieExclusive green he 25 c.s.i.Exclusive green he 35 c.s.i.Exclusive green he 25 r.s.i.Exclusive green he 35 r.s.i.

Tabla de contenido