Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment / Safety Function
Correction is necessary if the temperature measured
at the take off point differs from the temperature set on
the scale. For safety reasons and to prevent scalding
the safety function must be set to a maximum tempe-
rature of 42°C. To adjust please see page 24.
Operation 1384000
By turning the handle on the left hand side the
thermostatic mixer is opened, closed and the flow
can be changed from tub to shower function.
The temperature is selected by turning the graduated
handle on the right side.
Operation 138000
The mixer is operated by turning the handle on the
left hand side.
The temperature is selected by turning the graduated
handle on the right side.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Attention!
The mixer is equipped with non return valves.
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with national
or regional regulations (at least once a year)
8
English
Using the Ecostat in conjunction with
combination boilers.
When using the Ecostat with combination boilers,
the Ecostop ring 12 has to be removed (please see
page 22).
If fitting a hand shower remove the water limiter
from the shower.
If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Test certificate:
Anti-pollution function
Spare parts (see page 3)
1
thermoelement
2
shut off and diverter unit
3
handle
4
aerator cpl.
5
non return valve
6
noise reduction
7
s-unions
8
escutcheon
9
shut off unit
10 filter packing
max. 1 MPa
1,6 MPa
max. 80° C
65° C
20 l/min
WRAS
94282000
96509000
98664000
13485000
96737000
96429000
94140000
96467XXX
94149000
96922000