STOP
To stop operation turn the switch (2) to "0" if operation is manual,
or to room thermostat if operation is automatic.
Lastly, close the gas supply stopcock and turn off the isolation
switch.
The flame goes out and the fan motor will continue to run until the
combustion chamber has cooled down completely.
VENTILATION
To obtain the ventilation effect only, simply turn the switch (2) to
the position marked with the symbol
main fan starts while the burner stays off.
TRANSPORT AND HANDLING
The space heater can be lifted up and suspended using the four
anchor hooks provided in the casing.
Warning
Before moving the unit:
• Stop the machine as indicated in the "STOP"
paragraph;
• Disengage the power supply by removing the plug
from the power socket;
to start the machine: the
EN
• Fully unscrew the fitting that connects the gas pipe to
the heater;
• Wait until the heater has cooled down.
MAINTENANCE
For proper working efficiency the fans, the combustion chamber
and the burner must be cleaned periodically.
Warning
Before performing any maintenance operations:
• Stop the machine as indicated in the "STOP"
paragraph;
• Disengage the power supply by removing the plug
from the power socket;
• Close the gas supply stopcock;
• Wait until the heater has cooled down.
Cleaning must be carried out by removing any foreign bodies from
the fan suction grills.
Warning
Do not direct jets of compressed air towards the air
pressure intakes near the main fan: the air pressure
switch could be permanently damaged.
18