ENGLISH
etc.).
• Do not sit on or leave objects on the appliance.
This appliance can be used by
children no less than 8 years of
age and by individuals with
limited physical, sensory or
mental capacities, or by
inexperienced or untrained
individuals, provided that they
are supervised or have been
instructed in safe use of the
appliance and understand the
associated risks. Children must
not play with the appliance.
Cleaning and maintenance
procedures that can be
undertaken by the user must
not be entrusted to children,
unless under supervision.
Caution:
!
this symbol indicates that care must
be taken to avoid damaging the appliance
• Do not make modifications of any kind to this
appliance.
• Do not expose this appliance to the weather (rain,
sun, etc.).
• Regularly inspect the appliance for visible defects.
If any faults are found, do not operate the appliance;
contact Vortice immediately.
• If the appliance does not function correctly or
develops a fault, contact Vortice immediately.
Ensure that only genuine original Vortice spares
are used for any repairs.
• Should the appliance be dropped or suffer a heavy
blow, have it checked immediately by Vortice.
• The electrical system to which the appliance is
connected must conform to applicable standards.
• The appliance is double insulated and therefore
does not need to be earthed.
• The electrical power supply/socket to which the
appliance is to be connected must be able to provide
the maximum electrical power required by the
appliance. If it cannot do so, arrange for a qualified
electrician to make the necessary modifications.
• Switch off the system's main switch:
appliance does not function correctly; b) before
cleaning the inside and outside of the appliance;
c) if you decide not to use the appliance for any
length of time.
• Maintenance/Cleaning: On a yearly basis, have
professionally qualified personnel check the level of
grime that has accumulated. If necessary, use a dry
cloth or a brush to clean the control components and
fan blades. Water should only be used to clean the
adjustment vents. Do not immerse the appliance in
water or other liquids.
• Check that the air intake section, situated towards
the outside, is clear.
8
• The flow of air or fumes to be carried outside must
be clean (that is free of grease, soot, chemical and
corrosive agents, and explosive or flammable
mixtures).
• The appliance must not be used to activate water
heaters, room heaters, etc. and it must not discharge
into the hot air ducts of such appliances.
• Keep the appliance's intake and outlet grilles free to
ensure an optimum flow of air.
• Specifications for the power supply must correspond
to the electrical data on data plate A (fig.6).
The appliance must be
installed by a professionally
qualified electrician.
A multi-pole switch must be
used to install the appliance.
The contact opening gap must
be no less than 3 mm.
Air connection
The regulators for bathroom intakes
blanking plugs are fitted by pressing them onto the fan
casing and they are interchangeable. It is possible to
identify the two different regulator valves of the
regulators (15 m
The vents for the bathrooms, (
(
125) must be connected to the air extract
Ø
with ducts (use only 30m
Room
Kitchen
Utility room
Bathroom
Sanity
accommodation
These ducts must run as straight as possible, with a a
minimum length of 1.5 m of ducts for each extract.
a) if the
Ensure the pipes are positioned correctly on the
regulators.
Connect the air outlet
external extraction grille
Whole building
ventilation rate
3
3
/h or 30 m
/h) by their shape (fig. 5).
80) and kitchen
Ø
3
/h valves in the U.K.).
Continuous extract
Min
Min low rate
high rate
13 l/s
Total extract rate
8 l/s
must be at least
the whole building
8 l/s
ventilation rate
6 l/s**
125 to a roof terminal or an
Ø
Number of bedrooms
in dwelling
1
2
3
13
17
21
a b
(l/s)
80 and the
Ø
4
5
25
29

Publicidad