OPERATION
3
OPERATION
This equipment produces a fluid stream at
extremely high pressure. Read and understand
the warnings in the Safety Precautions section
at the front of this manual before operating this
equipment.
3.1
USING THE GUN TRIGGER LOCK
Always engage the gun's trigger lock when the gun is not in use.
1.
To lock the trigger, push in the trigger lock from left to right,
when looking at the rear of the gun.
2.
To unlock the trigger, push the trigger lock from right to left,
when looking at the rear of the gun.
1
GUN LOCKED
(GUN WILL NOT SPRAY)
3.2
PRESSURE RELIEF PROCEDURE
Be sure to follow the Pressure Relief Procedure
when shutting down the sprayer for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
1.
Lock the gun by pushing the gun trigger lock to the locked
position.
2.
Turn off the sprayer by moving the ON/OFF switch to the OFF
position.
3.
Turn the pressure control knob
counterclockwise to its OFF position in the
black zone.
4.
Flip the PRIME/SPRAY valve lever to the PRIME
position.
5.
Unlock the gun by pushing the gun trigger lock
to the unlocked position.
6.
Hold the metal part of the gun firmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
7.
Trigger the gun to remove any pressure
that may still be in the hose.
8.
Lock the gun by pushing the gun trigger lock to the locked
position.
6
2
GUN UNLOCKED
(GUN WILL SPRAY)
3.3
SETUP
Perform the following procedure before plugging in the power cord
of an electric unit.
1.
Ensure that the siphon tube and the return hose are attached and
secure.
2.
Using a wrench, attach a minimum of 50' of 1/4" airless spray
hose to the outlet fitting on the sprayer. Tighten securely.
3.
Attach an airless spray gun to the spray hose. Using two wrenches
(one on the gun and one on the hose), tighten securely.
Do not attach the tip to the spray gun yet. Remove
i
the tip if it is already attached.
Make sure all airless hoses and spray guns are
electrically grounded and rated at or above the
maximum operating pressure range of the airless
sprayer.
4.
Make sure the pressure control knob is in its OFF position in the
black zone.
5.
Make sure the ON/OFF switch is in its OFF position.
6.
Squirt a few drops of Piston Lube™ into the indicated area to
lubricate the packings.
Never operate unit for more than ten seconds
without fluid. Operating this unit without fluid will
cause unnecessary wear to the packings.
Attention
7.
Fully depress the pusher stem to make sure the inlet ball is
free.
8.
Make sure the electrical service is 120V, 15 amp minimum.
9.
Plug the power cord into a properly grounded outlet at least 25'
from the spray area.
Always use a minimum 14 gauge, three-wire
extension cord with a grounded plug. Never remove
the third prong or use an adapter.
Attention
After turning pump off, allow 30 seconds for the
power to completely drain from capacitors.
IMPACT X 440