Reduce the Sensor Range
The sensor is set for maximum range at the factory. If
the faucet is used on a very small or highly reflective
lavatory, the sensor range may be reduced by ap-
proximately 2".
Disconnect the power cable for approximately 10
seconds. Reconnect the power cable.
The LED will blink once to indicate that it is in the
"maximum range" mode.
When the LED stays on, cover the sensor window
with your hand or with a white card for 20 - 40
seconds to reset the electronics.
If the card or hand is removed in less
than 20 seconds, or after 40 seconds,
the sensor mode will not reset.
When the hand or card is removed, the LED will blink
-- once for "maximum range", twice for "reduced
range".
The LED will then stay on while the sensor recali-
brates itself.
When the LED turns off, the faucet is ready for use.