Troubleshooting
Problem
Possible Cause
Compressor does
not run.
Motor hums but
does not run or run
slowly.
Fuses blow or
circuit breaker trips
repeatedly.
Tank has insufficient
pressure.
No electrical power.
Blown stop/house fuse.
Tripped shop/home
breaker.
Thermal overload is open.
Loss of power or
overheating.
Pressure switch is bad.
Low voltage.
Wrong gauge wire or
length of extension cord.
Shorted or open motor
winding.
Defective check valve or
unloader.
Incorrect fuse size, circuit
overload.
Wrong gauge wire or
length of extension cord.
Defective check valve or
unloader.
13
Solution
When the tank pressure drops, the
compressor will turn on to cut-in
pressure.
Ensure the compressor is plugged
into a good outlet.
Replace the shop/house fuse.
Reset the shop/home breaker and
determine the underlying cause.
Unplug the compressor and wait
for it to cool. Then try using again.
If using an extension cord, check
for proper use.
Replace the pressure switch.
Check voltage with a voltmeter.
Verify proper gauge wire and cord
length are used.
Bring the compressor to a service
center.
Bring the compressor to a service
center.
Verify proper fuse size is being
used.
Use time-delay fuses.
Disconnect other electrical
appliances from the circuit or
operate compressor on its own
branch circuit.
Verify proper gauge wire and cord
length are used.
Bring the compressor to a service
center.
Please contact 1-888-43-HUSKY for further assistance.