PRIMING
Fill the pump completely with clean water
before switching it on. T he water should be
poured in through the priming plug (Fig.F).
When you have completed the
operation,screw the plug back in again and
start the pump. T he pump should be primed
again whenever it has not been used for a
long period of time or when air has made its
way into the system.
IMPORTANT
Never run the pump empty. lf this
happens by mistake,switch the pump
off,wait for it to cool down and then
prime it using clean water.
10
MAINTENANCE
Our pumps do not require any
maintenance provided one takes the
following precautions:
When there is a risk of freezing,
empty the pump through the drain
plug on the bottom of the pump
body,making sure you prime it
when subsequently starting it again;
check that the foot valve is clean at
regular intervals; if the pump is to
remain unused for a long period of
time (e.g. in the Winter) (Fig.G),it is
advisable to empty it completely,
rinse it with clean water and store it in a
dry place;
If the shaft does not turn freely,
release it using a screwdriver
inserting it in the special
slot(Fig.H);
If this is not sufficient to solve the
problem,remove the pump
body,undoing the relevant mounting
bolts,and clean it thoroughly to remove
any encrustation.
Never carry out any work on the pump
without having first disconnected it
from the mains supply.