Descargar Imprimir esta página

Abicor Binzel ABICAR 1200 PRO 42V Manual De Instrucciones página 48

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Putting into operation
6.5 Positioning the welding torch
The cross slide must be adjusted according to the welding torch type and diameter. The welding torch
position can be changed in the vertical and horizontal direction during welding using the cross slide.
Fig. 11
A Adjusting screw, vertical
B Bracket, horizontal
A
D
► Turn the adjusting screws (A) and (C) of the cross slide to the left or right.
The brackets (B) and (D) can be adjusted sidewise, or downwards and upwards.
6.6 Connecting the power supply/power source communication connection cable
The connection cable is not included in the scope of delivery.
 13 Accessories on page EN-29
Electric shock caused by damaged or improperly installed cables
The use of damaged or improperly installed cables may result in a potentially fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician only.
Risk of injury due to fire
A fire may occur due to improper use or connection. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate corresponds to the connection voltage.
► Insert the power supply/power source communication connection cable into the bushing.
EN - 18
Adjusting the cross slide
WARNING
WARNING
ABICAR 1200 PRO 42V
C Adjusting screw, horizontal
D Bracket, vertical
B
C

Publicidad