Descargar Imprimir esta página

Abicor Binzel ABICAR 1200 PRO 42V Manual De Instrucciones página 52

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Putting into operation
Setting the welding parameters
The following welding parameters can be set via the navigation.
Tab. 5
Parameters
Carriage speed
Weld length
Skipping
Crater fill
Backweld
Total length
Current lowering
Unit
Save setup
Load setup
Language
EN - 22
Welding parameters overview
Value
0.0–130.0 cm/min
1.0–250.0 cm
0.0–100.0 cm
0.0–3.0 s
0.0–2.0 cm
350–1000 cm, unlimited
Yes
NO
cm
in
1–40
1–40
ENGLISH
POLISH
SPANISH
FRENCH
PORTUGUESE
TURKISH
RUSSIAN
GERMAN
ITALIAN
ABICAR 1200 PRO 42V
Description
Welding tractor speed
Weld seam length
Distance between the weld seams.
Setting "0" will reset the crater fill time and
the crater back-filling. The device welds in
continuous welding mode.
Crater fill time.
Inactive at distance "0.0". Indicated by "!".
Length of the crater fill.
At maximum, the set weld length. Inactive at
distance "zero". Indicated by "!".
Total of all weld seam lengths and the
distance between the weld seams.
Infinite = The programme will be executed
until the device is manually switched off.
YES = The arc current is reduced during
crater fill.
The crater fill time must be greater than or
equal to the arc quenching time set on the
power source.
NO = The arc current is not reduced during
crater fill.
Unit used
Save the current configuration under
the indicated programme number.
Load the saved configuration under
the indicated programme number.
Language for menus

Publicidad

loading