Descargar Imprimir esta página

Galletti DUCTIMAX i Serie Manual De Instalación, Uso Y Mantenimiento página 25

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DUCTIMAX i
Speed
Declared speed
Control voltage DF 1R
(E)
Rated air flow DF 1R
(E)
Available static pressure DF 1R
(E)
Power input DF 1R
(E)
Maximum current absorption
Total cooling capacity DF 1R
(1)(E)
Sensible cooling capacity DF 1R
(1)(E)
FCEER class DF 1R
(E)
Water flow DF 1R
(2)
Water pressure drop DF 1R
(2)(E)
Heating capacity DF 1R
(3)(E)
FCCOP class DF 1R
(E)
Water flow DF 1R
(3)
Water pressure drop DF 1R
(3)(E)
Total sound power level DF 1R
(4)
Additional coil DF - number of rows
Inlet + radiated sound power level DF 1R (4)(E)
Outlet sound power level DF 1R
(4)(E)
Water content - additional coil DF 1R
Cross-section area of power cables
(5)
Power supply cable type
Safety fuse F
Fuses type
DUCTIMAX i
Speed
Declared speed
Control voltage DF 1R
(E)
Rated air flow DF 1R
(E)
Available static pressure DF 1R
(E)
Power input DF 1R
(E)
Maximum current absorption
Total cooling capacity DF 1R
(1)(E)
Sensible cooling capacity DF 1R
(1)(E)
FCEER class DF 1R
(E)
Water flow DF 1R
(2)
Water pressure drop DF 1R
(2)(E)
Heating capacity DF 1R
(3)(E)
FCCOP class DF 1R
(E)
Water flow DF 1R
(3)
Water pressure drop DF 1R
(3)(E)
Total sound power level DF 1R
(4)
Additional coil DF - number of rows
Inlet + radiated sound power level DF 1R (4)(E)
Outlet sound power level DF 1R
(4)(E)
Water content - additional coil DF 1R
Cross-section area of power cables
(5)
Power supply cable type
Safety fuse F
Fuses type
(1)
Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) according to EN1397:2015
(2)
Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity)
(3)
Water temperature 65°C / 55°C, air temperature 20°C
(4)
Sound power measured according to standards ISO 3741 and ISO 3742
(5)
The shown section is to be considered as the minimum recommended section. The cables must be chosen in compliance with CEI - UNEL 35024/1. standard.
(E)
EUROVENT certified data
Power supply 230-1-50 (V-ph-Hz)
33
min
med
max
1,6,7
V
4,50
7,40
8,30
m³/h
195
357
398
Pa
19
50
63
W
10
26
35
A
0,84
kW
1,46
2,31
2,56
kW
1,03
1,73
1,92
l/h
252
402
445
kPa
2
5
5
kW
2,09
3,09
3,29
l/h
183
271
288
kPa
2
3
4
dB(A)
39
50
54
3+1
dB(A)
37
48
52
dB(A)
36
47
51
dm³
0,59
mm²
1,00
A
1
53
min
med
max
1,6,7
V
3,40
7,60
8,50
m³/h
333
683
755
Pa
12
50
61
W
11
54
67
A
0,91
kW
2,29
4,32
4,72
kW
1,67
3,19
3,48
A
l/h
394
749
822
kPa
2
7
8
kW
3,40
5,17
5,45
A
l/h
297
452
477
kPa
6
13
14
dB(A)
38
55
58
3+1
dB(A)
36
53
56
dB(A)
35
52
55
dm³
0,97
mm²
1,00
A
1
34
min
med
max
min
1,6,7
4,50
7,40
8,30
5,40
195
357
398
302
19
50
63
17
10
26
35
21
0,84
1,59
2,72
3,01
1,95
1,09
1,89
2,09
1,47
A
274
473
522
339
3
7
9
3
2,09
3,09
3,29
2,80
A
183
271
288
245
2
3
4
3
39
50
54
38
4+1
37
48
52
36
36
47
51
35
0,59
1,00
N07V-K
1
gG
54
min
med
max
min
1,6,7
3,40
7,60
8,50
6,80
333
683
755
1050
12
50
61
40
11
54
67
105
0,91
2,51
4,88
5,32
6,28
1,77
3,43
3,74
4,64
A
432
846
925
1094
3
10
12
13
3,40
5,17
5,45
6,42
A
297
452
477
562
6
13
14
19
38
55
58
61
4+1
36
53
56
59
35
52
55
58
0,97
1,00
N07V-K
1
gG
43
44
med
max
min
med
1,4,7
1,4,7
8,30
9,90
5,40
8,30
524
642
302
524
50
75
17
50
50
77
21
50
0,84
0,84
3,22
3,75
2,33
3,82
2,44
2,89
1,62
2,66
562
656
403
664
8
11
6
13
3,82
4,24
2,80
3,82
334
371
245
334
5
6
3
5
52
58
38
52
3+1
4+1
50
56
36
50
49
55
35
49
0,59
0,59
1,00
1,00
1
1
63
64
med
max
min
med
5,6,7
5,6,7
7,50
8,30
6,80
7,50
1163
1289
1050
1163
50
60
40
50
128
162
105
128
3,52
3,52
6,81
7,38
7,04
7,64
5,03
5,46
4,96
5,38
C
B
1190
1295
1225
1332
16
18
20
23
6,73
7,06
6,42
6,73
C
C
589
618
562
589
21
22
19
21
63
69
61
63
3+1
4+1
61
67
59
61
60
66
58
60
0,97
0,97
1,50
1,50
2
2
UT66002794
max
9,90
642
75
77
4,51
3,15
788
18
4,24
371
6
58
56
55
max
8,30
1289
60
162
8,28
5,84
1448
26
7,06
618
22
69
67
66
25

Publicidad