Operating Instructions
Safety Switch TP-TW... (Twin)
Inspection and service
WARNING
Danger of severe injuries due to the loss of the
safety function.
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
correct switching function
f
secure mounting of all components
f
damage, heavy contamination, dirt and wear
f
sealing of cable entry
f
loose cable connections or plug connectors.
f
Info: The year of manufacture can be seen in the
bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety regula-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and application as per the requirements
of
a copper wire for the temperature range
60/75 °C must be used.
EU declaration of conformity
The declaration of conformity is part of the operating
instructions.
The complete EU declaration of conformity can also
be found at www.euchner.com. Enter the order num-
ber of your device in the search box. The document
is available under Downloads.
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Germany
Service telephone:
+49 711 7597-500
E-mail:
support@euchner.de
Internet:
www.euchner.com
Technical data
Parameter
Value
Housing material
Reinforced thermoplastic
Degree of protection acc. to
IP67
IEC 60529
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
-20 ... +55 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation orientation
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
20 N
Retention force
10 N
Actuating force, max.
10 N
Actuation frequency
1,200/h
Switching principle
Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection
Cable entry
Conductor cross-section
0.34 ... 1.5 mm²
(flexible/rigid)
Operating voltage for optional
L024 24 V
LED indicator
Rated insulation voltage
U
= 250 V
i
Rated impulse withstand
U
= 2.5 kV
voltage
imp
Conditional short-circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Utilization category acc. to
AC-15 4 A 230 V /
EN 60947-5-1
DC-13 4 A 24 V
Switching current, min., at
1 mA
24 V
Short circuit protection
(control circuit fuse) acc. to
4 A gG
IEC 60269-1
Convent. thermal current I
4 A
th
Solenoid operating voltage/
AC/DC 24 V (+10%/-15%) 8 W
solenoid power consumption
Duty cycle
100%
Locking force with
F
max
ACTUATOR P-... and
HINGED ACTUATOR P-...
1,300 N
Reliability values acc. to EN ISO 13849-1
B
2 x 10
10D
6
at DC-13 100 mA / 24 V
1) Refer to the EU declaration of conformity for the issue date
8
F
Zh
1,000 N
1)