Descargar Imprimir esta página

EUCHNER TP-TW Serie Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Safety Switch TP-TW... (Twin)
With plug connector SR6/
With auxiliary key release
Fig. 3: Dimension drawing for TP‑TW...
h
31
h
0,3
72
16
30
34,5
<40>
<42>
3,5
33,5
SR11
19
Necessary minimum travel + perm. overtravel
Approach direction
Standard actuator
Horizontal (h)
Vertical (v)
h
Auxiliary key release
Ø 5.3 (2x)
for M5 x 35 mm
ISO 1207/ISO 4762
M = 1.5 Nm
Do not use these
mounting holes!
M = 0.8 Nm
red
green
LED module en-
closed separately.
Observe assembly
instructions.
Ø 5.3 (2x)
for M5 x 35 mm
ISO 1207/ISO 4762
M = 1.5 Nm
Auxiliary release with triangu-
(2 triangular keys included)
0,3
3,5
33,5
Lock function
Type
Lock
TP...C2184
Identical locking
9
Overtravel actuator
28 + 2
28 + 7
29.5 + 1.5
28 + 7
Auxiliary release
Locking screw
lar wedge
Direction of rotation
Marking
Key removable in position
and
Key to symbols
Guard locking ready for operation
/
Guard locking released
/