WIKA 55 Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Commissioning, operation
When mounting a bimetal thermometer that can be rotated and
swivelled, the specific instructions must be followed. In order to set
the indicator to the desired position, the following steps must be
EN
taken:
1. The lock nut or union nut must be loosened at the process
connection.
2. The hexagon bolts and slotted screws at the swivel joint must be
loosened.
3. Position the indicator as required, tighten the hexagon bolts and
slotted screws, and finally tighten the lock nut or union nut firmly.
14
loosening
Make sure to loosen the screws
on the opposite side as well!
WIKA operating instructions model 55

Publicidad

Tabla de contenido
loading

Tabla de contenido