Descargar Imprimir esta página

PLYMOVENT MISTELIMINATOR BANKS Manual De Instalación Y De Manejo página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
Fig. 6.1: Controls
6.3
Filter replacement
Differential pressure gauges on each filter module indicate when
the filters must be replaced. Except for the HydroFilter and the
mesh filter, the filters cannot be cleaned.
The table below shows the max. pressure level at which filter
replacement is required.
Filter type
Bag filter
Oil mist cassette OC-1
Oil mist cassette OC-2
HEPA filter
WARNING!
Always wear face mask and protective gloves during
filter replacement.
WARNING!
Always turn off the connected extraction system
before filter replacement.
To replace any filter, proceed as follows.
Fig. 6.2
Open the door of the filter module in question.
Unlock the filter by pulling the straps.
Remove the filter.
Dispose of the used filter in accordance with state or local
regulations.
Clean the inside of the filter housing.
Place a new filter and lock it by pushing the strap bars.
Close and lock the door.
Fig. 6.2: Filter locking device
ATTENTION!
Observe the airflow direction of the filters to be from
bottom to top. The correct airflow direction is indicated
by an arrow.
6.4
Filter cleaning
The HydroFilter and the aluminium mesh filter must be cleaned
on a regular basis (refer to paragraph 6.1).
0000101016/150119/C MistEliminator | Filter banks
A
B
C
Filter replacement at
500 Pa (2.0 in. WG)
500 Pa (2.0 in. WG)
800 Pa (3.2 in. WG)
800 Pa (3.2 in. WG)
To clean the filters, proceed as follows.
Open the door of the lowest filter module (OC-1 or bag filter)
and take out the filter cassette to get access to the
HydroFilter and mesh filter.
Remove the mesh filter and the HydroFilter.
Clean them with industrial detergent, e.g. Plymovent EFC.
Mount all filters in reverse order and close the door. Make
sure the OC-1 or bag filter is securely locked.
7
TROUBLESHOOTING
If the system does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
Symptom
Problem
Oil leakage
Pollution of
inside filter
filter housing.
module.
8
SPARE PARTS
The following spare parts are available for the product.
8.1
ME-31 / ME-32 (F1 / F2)
Refer to exploded view Fig. II on page 61.
Article no.
Description
0000100186
HFME-3 / HEPA final filter
0000100188
BFME-31 / Bag filter
0000100823
Oil container (8 liters)
0000100824
ME-INL/IMP / HydroFilter (impinger)
0000100825
ME-INL/PF / Pre filter
0000101330
Lock with handle (set of 2)
0000101333
Cassette/bag lock (set of 2)
0000101335
Lower door of bag filter module, incl. locks, hinges and
sticker
0000101336
Upper door of bag filter module, incl. locks, hinges and
sticker
0000101337
Bag filter suspension (set of 2)
0000101338
Aluminium suspension rod Ø 12 mm (set of 2)
0000101339
Door of HEPA filter module, incl. locks, hinges and
sticker
0000101342
Fan wheel 1,1kW/50Hz
0000101343
Fan wheel 1,1kW/60Hz
0000101345
Motor 1,1 kW; 208-220/460V/3ph/60Hz
0000101346
Fan wheel 2,2kW/50Hz
0000101347
Fan wheel 2,2kW/60Hz
0000101348
Motor 2,2 kW; 230-400V/3ph/50Hz
0000101349
Motor 2,2 kW; 208-220/460V/3ph/60Hz
0000102753
Adjustable foot
0040900040
Pressure gauge Ø 63 mm (metal ring)
8.2
ME-41 / ME-42 (F1 / F2)
Refer to exploded view Fig. III on page 61.
Article no.
Description
0000100186
HFME-3 / HEPA filter for final filtration
0000100357
OC-2 / Coalescer filter cassette stage 2
0000100358
OC-1 / Coalescer filter cassette stage 1
Possible cause Solution
Filter(s) placed
Place filter(s)
incorrectly.
correctly and lock
them.
Sealing material
Replace filter(s).
of filter(s)
damaged or
loose.
EN - 9

Publicidad

loading