Tour Series TKO
Combo
®
NOTE: All specifications tested
with mains voltage maintained
at nominal level.
Line Voltage:
100V - 120V / 220V - 240V
50/60 Hz
CAUTION: Do not switch line
voltage while unit is powered
on. Doing so may cause dam-
age to unit.
Typical Power Consumption:
25 W Idling / 300 W @ 200 W into
4 ohms
Power Amplifier Specifications:
Protection:
DDT™ speaker protection with
defeat switch
Short Circuit protection
Thermal protection circuit
Current limit protection circuit
DC output protection circuit
Minimum Load:
4 ohms (Internal Speaker = 8 ohms)
Input Sensitivity:
(Signal into return jack with master
volume set to full CW): 1 V RMS
Extension Speaker Output Jack =
One 1/4" jack in parallel with
internal 15" speaker
NOTE: All specifications tested with mains voltage maintained at nominal level;
Features and specifications subject to change without notice.
All manuals and user guides at all-guides.com
Tour
Series Specifications
™
CAUTION: Do not use an exten-
sion speaker with impedance
lower than 8 ohms.
Power Output:
All measurements with no more than
1% THD + N
8 ohms 100 watts (28.4 VRMS)
4 ohms 200 watts (27.0 VRMS)
Headphone Amplifier
Specifications:
Stereo 8 ohm minimum load
Power Output:
All measurements with no more than
1% THD + N
8 ohms 250 mW (1.41 VRMS) x2
Preamplifier Specifications
Settings for the following
measurements (unless
otherwise stated):
PRE GAIN: 5 (12 o'clock)
BRIGHT: Out
CONTOUR: out
LOW: 0 (12 o'clock)
HIGH: 0 (12 o'clock)
GRAPHIC EQ: All sliders set to center
GRAPHIC EQ Switch = Out
MASTER GAIN: 10 (fully clockwise)
DDT
: Active
™
all tested with 1kHz sine wave source
Input Sensitivity (input selector
set to active):
Nominal Input: -3.80 dBu
Minimum Input: -31.3 dBu
Maximum Input: 10.2 dBu
(maximum signal at input before
clipping)
D.I. XLR Output:
Balanced output driven pre-EQ by
buffered instrument signal.
Weight:
73.4 lbs.
Dimensions (h x w x d):