Display Section
For purposes of this explanation,
all parts of the display are shown.
During actual operation, only the
relevant items will be displayed.
Shows the operating mode, etc.
* Multi language display is sup-
ported.
Indicates that operation of the re-
mote controller has been prohibited
by a master controller.
Indicates that the timer is off.
Shows the target temperature.
Operation Section
Set Temperature buttons
Down
Up
Timer Menu button
(Monitor/Set button)
Mode button (Return button)
Set Time buttons
Back
Ahead
Timer On/Off button
(Set Day button)
Opening the
lid
Note:
"PLEASE WAIT" message
This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power fail-
ure.
"NOT AVAILABLE" message
This message is displayed if a button is pressed to operate a function that the indoor unit does not have.
If a single remote controller is used to simultaneously operate multiple indoor units that are different models, this message will not be displayed if
any of the indoor units is equipped with the function.
4
Day-of-Week
Shows the current day of the week.
Shows the current time, unless the simple or Auto Off
timer is set.
If the simple or Auto Off timer is set, shows the time re-
maining.
TIME SUN MON TUE WED THU FRI SAT
TIMER
AFTER
ERROR CODE
F C
ONLY1Hr.
-
cator
The indicator
shows the direc-
Displayed if the airflow is set to
low and downward during COOL
or DRY mode. (Operation varies
according to model.)
The indicator goes off after 1 hour
when the airflow direction also
changes.
TEMP.
MENU
ON/OFF
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
Hr
ON
AFTER
OFF
FUNCTION
F C
FILTER
WEEKLY
SIMPLE
AUTO OFF
Shows the room temperature. The room
temperature display range is 8–39 °C.
The display blinks if the temperature is
less than 8 °C or 39 °C or more.
Louver display
Indicates the action of the swing louver.
Does not appear if the louver is station-
ary.
Indicates that the power is on.
ON/OFF
FILTER
CHECK
TEST
OPERATION
CLEAR
Built-in temperature sensor
Displayed when the remote controller
sensor is used.
Indicates that remote controller but-
tons have been locked.
Comes on when it is time to clean the
The indicator comes on if the corre-
sponding timer is set.
Fan Speed indicator
Shows the selected fan speed.
Ventilation indicator
Appears when the unit is running in
Ventilation mode.
ON/OFF button
Fan Speed button
Filter
button
(<Enter> button)
Test Run button
Check button (Clear button)
Louver button
(
Operation button)
To return operation
number
Ventilation button
(
Operation button)
To go to next opera-
tion number