1
EN
3
Main screen
The main screen of the secondary controller displays the
data for the rundown performed, see Figure 01, Page 3.
Item
Description
1
Tool number
2
Status result
3
Torque result
4
Angle result
5
Status strip
6
Node address device
7
LED strip
3.1 Tool number
The current tool number is displayed in the header. The
number corresponds to the set node address.
3.2 LED strip
The four fields in the LED strip correspond to the configu-
rable LED light rings on the NeoTek tool and light up in the
colors red, green, yellow and blue.
Color
Explanation
Red
Rundown NOK
Green
Rundown OK
Yellow
Status
Blue
Not connected as standard, can be
programmed at will
3.3 Status result
The status result displayed is made up of:
the application (App)
the stage
the status
Application
The application can be selected on the master or primary.
Up to 99 applications are possible whose settings can be
individually programmed.
Stage
The stage shows the stage currently reached and the total
number of stages to the end of a rundown.
Example: Stage 2 / 3 (current stage: 2, total number of
stages: 3)
Status
The status indicates whether the rundown performed was
correct (OK) or not (NOK). NOK occurs when the mea-
sured rundown values for torque or angle of rotation are
not within the programmed tolerance.
6
3.4 Torque result
This field is made up of the torque for the rundown and its
unit.
Background color
The background color to the field indicates whether the
result is OK.
Background
color
Red
Green
Yellow
Unit
The unit can be changed in the master or primary:
1.
Navigator > Advanced > Controller > General
2.
Under Custom Torque units there is a dropdown menu
Torque in which one of the following units can be
selected: Nm, FtLbs, InLbs, dNm or CUSTOM
Peak torque
If a peak torque is set in the master or primary, the peak
torque is marked with a leading "P".
The peak torque can be activated in the master or primary:
1.
Navigator > Standard > Select application > Stages
2.
Activate the control box Show peak torque.
3.5 Angle result
This field shows the angle result and its unit.
Background color
The background color to the field indicates whether the
result is OK.
Background
color
Red
Green
Yellow
P2379PM | 2019-04
Explanation
The torque for the rundown is higher
than the defined torque (NOK)
The torque for the rundown corre-
sponds to the defined parameters
(OK)
The torque for the rundown is lower
than the defined torque (NOK)
Explanation
The angle for the rundown is higher
than the defined angle (NOK)
The angle for the rundown corre-
sponds to the defined parameters
(OK)
The angle for the rundown is higher
than the defined angle