Descargar Imprimir esta página

Cleco mPro400GCD-S Manual De Instrucciones página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

3.6 Status strip
The current rundown status is displayed in the top two lines
of the status strip.
Status message
No communication with
master
Rundown in progress
Tightening done - Result
NOK
Tightening done - Result
OK
Errors are displayed in the bottom lines of the status strip
(e.g. Ems error [1000]: Tool disconnected).
3.7 Node address device
The node is used by the master or primary controller for
unambiguous assignment of the tools and secondary con-
trollers. Every secondary controller requires a separate
node address to make unambiguous communication with
the master or primary controller possible and to guarantee
functionality.
1.
To display or edit the node address, click on <Setup>.
→ A window with the following options opens:
Option
Node address
<Setup node adress>
<Back>
2.
To edit the node address, click on <Setup node
address>.
3.
Enter the password. The password is predefined:
0736381254
4.
Increase the number of the node address with the
key or reduce it with
<OK>.
Numbers between 1 and 32 can be
selected for the node address.
Node address 1 should only be used if the
secondary controller is connected to a
master controller as this has no tightening
module. The primary controller contains a
tightening module assigned as standard to
the first node address.
5.
Confirm the following message Save and Reboot?
with <Yes>.
→ The secondary controller executes a reboot. The
node address is then changed.
Apex Tool Group
Explanation
No connection to master/
primary
Status during rundown
Rundown complete, result
NOK
Rundown complete, result
OK
Description
Current node address
Set up the node address
Back to main menu
and confirm with
P2379PM | 2019-04
Duplicate node addresses
After the node address has been changed, the secondary
controller checks whether the selected address has
already been assigned to another device. If this is the case,
the message Duplicate node detected!!! appears after
the node address has been changed.
To duplicate a node address:
1.
Confirm the message Duplicate node detected!!!
with <OK>.
2.
Confirm the message Save and Reboot? with <Yes>.
3.
Confirm the message Are you sure to accept dupli-
cate node? with <Yes>.
→ If a node adress is duplicated, the secondary con-
troller will no longer communicate with the master
or primary controller.
1
EN
7

Publicidad

loading

Este manual también es adecuado para:

Mpro400gcd-h