Installation
Select Reading :
4-20mA
PULSE
System Units :
4-20mA
PULSE
Flow Units :
4-20mA
PULSE
Instrument Type :
4-20mA
Heating / Chiller
PULSE
Instrument Side :
4-20mA
Return / Flow
PULSE
Instrument Fluid :
4-20mA
Glycol / Water
PULSE
Set Separation :
4-20mA
PULSE
Checking Signals
4-20mA
Searching . . .
PULSE
14
Flow|Vel
litres | m3
l/min | l/s
12.4mm
►Select to read flow or velocity using
►Press
to acknowledge.
►Select the system units using
►Press
to acknowledge.
►Select the FlowUnits using
►Press
to confirm the Flow Units.
HM versions only:
►Select the instrument type using
►The unit is preconfigured for Heating applications.
►Press
to confirm the setting.
HM versions only:
►Select which side the electronics unit is installed using
►The unit is preconfigured for Return.
Press
to confirm the setting.
►Select your instrument fluid and press
►The GF U1000 V2 WM/WHM shows you the correct transducer
distance for your application.
►Press
to acknowledge
►Proceed with 1.1
The GF U1000 V2 WM/WHM searches for a valid signal.
User Manual
.
.
.
.
to acknowledge.
.