Transit-time
1
± 50 ps
100:1
0.1m/s to 10m/s (0.3 ft/s - 32 ft/s)
High purity water, clean water with < 3 percent by volume of particle content, or up to
30% ethylene glycol.
± 3 % of flow value with a flow rate of > 0.3 m/s
± 0.15 % of measured value
25 to 115mm OD and 125 to 225mm OD
Note: Pipe size is dependent on pipe material and internal diameter.
Flow rate
m/s, ft/s
Volume flow
l/s, l/min, m
gal/s, gal/min, USgal/s, USgal/min
Volume
l, m
English
12 to 24 V (AC or DC) or 24 VAC
7 W (DC) or 7 VA (AC) max.
Opto-isolated MOSFET volt free contact (NO/NC)
2500 V
Default value
50 ms
Programmable
3 to 99 ms
range
Up to 166 pulses/s (depending on pulse width)
200 Hz max. (Range 1 to 200)
24 V AC / 500 mA
4 to 20 mA
0.1 % of total scale
620 Ω
1MΩ @ 100V
3.5 mA
RTU
1200, 2400, 4800, 9600, 19200, 38400
8-None-2, 8-None-1, 8-Odd-2, 8-Even-1
PI–MBUS–300 Rev. J
RS485
1MΩ @ 100V
PT100 Class B 4 wire
2 to 85°C (36 to 185°F)
0.1°C / 1°F
±0.725°C (±1.305°F)
/min, m
/hr
3
3
, gals, USgals
3