Password-protected menus
Attach Sensors :
4-20mA
PULSE
Calibrate #1 :
4-20mA
H99.9 / C99.9 : 1.00
PULSE
6.11
Volume totals menu
Reset Vol. Total :
4-20mA
PULSE
NOTICE
If the totalizer is activated, the display switches back and forth between the flow value and the total.
► Press the
button
Each screen is displayed for 30 s.
6.12
Diagnostics menu
The diagnostics menu provides additional information and various diagnosis options.
The menu can be accessed by pressing the
Press the
and
keys to move between the diagnostics screens.
Press
to exit the Diagnostics menu.
Est. TA
4-20mA
Act. TA
PULSE
Pulse :
4-20mA
100.00 Hz
PULSE
34
Press Enter
NO | YES
key from the main flow-reading screen.
161.39 us
162.85 us
Frequency
HM versions only
► You are prompted to attach the sensors. Place the PT100
sensors touching each other and allow their temperature to
stabilise for 1 minute.
► Press
to continue.
HM versions only
► The unit calculates the temperature offset.
► When the procedure is complete, the Zero Temp Offset
screen is displayed with NO selected.
► Press
to return to the Main Menu.
► To zero the Volume Totals value, select Yes.
► Press
to confirm the action and return to the Main Menu.
The Estimated TA (Time of Arrival) and Actual TA show the
theoretical and measured transit times.
If the actual value is displayed as 9999.99 then a usable signal
could not be detected.
Displays the pulse status (for example):
Deactivated, Volume 0.000 litres, Signal Loss, Alarm(On) 500.0 l/
min, Alarm(Off) Signal Loss, Frequency 100.00 Hz.