User Manual
6.6
Setup
Select Dims :
4-20mA
PULSE
Pipe Material :
4-20mA
PULSE
Enter Pipe ID :
4-20mA
PULSE
Wall Thickness :
4-20mA
PULSE
Temperature :
4-20mA
PULSE
System Units :
4-20mA
PULSE
Flow Units :
4-20mA
PULSE
Select Reading :
4-20mA
PULSE
mm | inches
Plastic
050.0 mm
004.37 mm
017.0 oC
Litres \ m3
l/min | l/s
Flow/Vel
► Choose whether to use imperial or metric units (default).
► If "inches" option is selected, the temperatures will be
displayed in °F and the energy values will be in BTUs.
The following diagrams show the metric options only.
► Select the pipe material by using the
scroll through the list.
Press
to confirm the material.
► You are then prompted to enter the internal diameter of the
pipe:
Use the
,
and
to confirm the value. Depending on configuration of the
unit, valid values are in the range : 20 -110mm (0.787– 4.33
inches) or 105 – 215mm (4.13 – 8.46 inches).
► Enter the wall thickness of the pipe:
Use the
,
and keys to change the value.
Press
to confirm the value.
► Enter the temperature of the fluid. The value must be in the
range 0.0 – 135.0°C.
► Choose the System Units. If you selected mm in the first step
(Select Dim), the choice is litres or m
the choice is Imperial gallons or US gallons.
► Choose the Flow Units. If you selected mm in the first step
(Select Dims), the choice is l/min or l/s. If you selected Inches,
the choice is gal/min or gal/hr (with either Imperial or US
gallons according to the System Units selection).
► Choose the default display option: Flow (flow rate, for exam-
ple, l/min) or Vel (velocity, for example, m/s).
Password-protected menus
and
keys to
keys to change the value. Press
. If you selected Inches,
3
29