Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 13)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance (see page 16)
Dimensions (see page 14)
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- EcoSmart® dirty or leaking
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Crossflow
Assembly (see page 11)
English
Flow diagram (see page 14)
free flow
Spare parts (see page 18)
+
Special accessories (see page 18)
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough) #13597000
Cleaning (see page 15)
Operation (see page 15)
Test certificate (see page 14)
65°C
Remedy
- Clean or exchange EcoSmart®
(see page 16)
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange cartridge