INFORMATOIN NOISE / MEAN ACCELERATION VALUE
The tools are suppressed in accordance for the prevention and elimination of radio
disturbances measured in accordance with standard: EN 60745
Sound pressure level / Sound power level
L PA
L WA
dB(A)
BA 31ES
90
101
DANGER
The indicate measurements refer to new power tools.
Daily usa causes the noise and vibration values to change.
Displayed emission values are comparative and are to be employed for
a provisional assessment of the operator's risk exposure during the work period.
Appropriate evaluation of work period must also include tool's idle and stop
periods. These emission values represent the tool's main applications.
If the tool is used for other applications, with other accessories, or if it does not
undergo regular maintenance, emission values can significantly increase
during operations.
Use hearing protection!
PARTS OF THE TOOL
1 - Technical data identification label
2 - ON/OFF switch
3 - Speed control
4 - Wheel spindle locking button
5 - Spindle
6 - Side handle
7 - Adjustable protective shield
8 - Dust brush
9 - Collar with protective shield fixing points
10 - Protective shield fixing screws
11 - Disc pad tapered ring nut
12 - Abrasive disc mouting plate
13 - Spanners
14 - Motor ventilation slots
15 - 29 mm Ø suction port
STARTING UP
WARNING
Pay attention to the mains voltage! The mains voltage must
correspond to the voltage indicated on the technical data identification
label (1).
DANGER
Before any intervention on the electrical tool take the plug
out from the socket
3 axis vibration level
(Surface
grinding))
a h
Uncertainty
Uncertainty
2
m/s
3
5,50
1,50
BEFORE STARTING THE TOOL
Before starting-up the tool, ensure that:
- the packaging is complete and does not show signs of having been damaged
during storage or transport;
- the tool is complete; check that the number and type of components comply
with that reported in this instruction booklet;
- the power supply and socket outlet can support the load reported in the table
and that indicated on the tool identification plate reproduced;
- the power supply cable and plug are in perfect condition;
- the ON/OFF switch (2) works properly though with the power supply
disconnected;
- the wheel spindle locking button (4) is released (rotate the abrasive wheel by
hand for at least one revolution);
- all the parts of the tool have been assembled in the proper manner and that
there are no signs of damage;
- the ventilation slots (14) are not obstructed.
ASSEMBLING THE TOOL
DANGER:
never work without protective earmuffs (7)
Wear protective gloves!
- screw in the auxiliary handle (6); the handle can be mounted on the left or
right of the tool body;
- mount the dust brush (8) securely on the protective shield (7) (pushfit);
- mount the protective shield (7) with collar on the body of the tool using the
screws (10). Ensure that the protrusions on the collar (9) are inserted in the slots
cut into the flange of the adjustable protective shield (7);
- after tightening the screws (10) and collar (9), the adjustable protective shield
(7) must be able to rotate with a slight resistance approximately 20° in order
that it may be positioned as desired;
- connect the extraction device by the suction pipe in the nozzle (15).
The protective shield (7) must be mounted around the handle.
ASSEMBLY OF THE DISC HOLDER SANDING PAD AND THE
ABRASIVE DISC
1.Insert the disc pad (12) on the spindle (5);
2.fit the abrasive disc;
3.screw on the ring nut (11) and tighten it using the pin wrench (13) preventing
the spindle from moving with the 17 mmspanner or with the spindle locking
button (4).