Tools Required
Phillips screw driver or straight slotted screw
driver, adjustable wrench, step ladder, and
wire cutters.
Mounting Options
If there isn't an existing electrical box, then
read the following instructions. Disconnect
the power by removing fuses or turning off
circuit breakers.
Secure the electrical box directly to the building
structure. Use appropriate fasteners and
building materials. The electrical box and
its support must be able to fully support the
moving weight of the fan (at least 35 lbs.).
Do not use plastic electrical boxes.
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK
OR
PERSONAL
INJURY,
TO OUTLET BOX MARKED "ACCEPTABLE
FOR FAN SUPPORT OF 35LBS. (15.9 KG) OR
LESS", AND USE SCREWS PROVIDED WITH
THE
OUTLET
BOX.
ELECTRICAL
COMMONLY
USED
FOR
OF
LIGHTING
FIXTURES
ACCEPTABLE
FOR
FAN
SUPPORT
MAY NEED TO
BE REPLACED. CONSULT A
QUALIFIED ELECTRICIAN IF IN DOUBT.
3. Installing Your Fan
Figures 1, 2, and 3 are examples of different
ways to mount the electrical box.
MOUNT
BOXES
THE
SUPPORT
MAY
NOT
BE
AND
Note: You may need a longer downrod to
maintain proper blade clearance when
installing on a steep, sloped ceiling.
The maximum angle allowable is 20˚. If the
canopy touches downrod, turn the canopy
180˚ before attaching the canopy to the
Figure 1
mounting plate.
To hang your fan where there is an existing
fixture but no ceiling joist, you may need an
Figure 2
installation hanger bar as shown in Figure 4.
Figure 3
Figure 4