Descargar Imprimir esta página

iPower SUA2000iP Manual Del Propietário página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

CONTROL PANEL FEATURES
1. Low Idle Switch: Low idle switch minimizes fuel
consumption and noise by adjusting the engine speed
to the minimum required for the current load.
2. Overload Indicator LED (Red): Illuminates when the
generator is overloaded which means the generator's
wattage / amperage capacity has been exceeded by
connected electrical devices or by a power surge.
When this occurs, the Output Ready Indicator LED will
go off. The engine will continue to run, but the red
Overload Indicator LED will stay on, and power will no
longer be supplied to connected electrical devices.
To rest the generator:
Remove all applied loads and stop the engine. Review
for any faulty or shorted connections.
Start the generator and reconnect electrical devices
sequentially, allowing the generator to stabilize after
each device is connected. Make sure the total wattage
of connected electric devices are not exceeding
recommended rated output power.
3. Output Ready Indicator LED (Green): Illuminates
when the generator is operating normally and indicates
the generator is producing electrical power at the
receptacles.
4. Oil Warning Indicator LED (Red): Illuminates when the
engine oil level falls below the safe operating level and
the generator will automatically shut off the engine. The
engine will not start until the proper amount of oil is in
the crankcase.
NOTE: Total power drawn from all outlets must not exceed the nameplate rating.
1
12
11 10
Page 09
2
3 4
5
6
9
5. 5V DC, Outlets: Provides 5 volt DC power
up to 2.4 amps.
6. CO(Carbon Monoxide) WATCH-GUARD Indicator
Light (Red for Shutoff and Yellow for Service):
The CO(Carbon Monoxide) WATCH-GUARD
monitors for the accumulation of poisonous CO
gas around the generator produced by engine
exhaust when the generator is running. If the CO
WATCH-GUARD detects increasing levels of CO
gas, it automatically shuts off the engine. See CO
WATCH-GUARD section for more information.
7. Starting Dial Switch: Used to start and stop the
generator.
8. Parallel Operation Outlets: These outlets are used
for connecting two AIPOWER inverter generators
for parallel operation. Do not connect or disconnect
parallel cables while the generator is running to avoid
damage.
9. 120V AC, 30A Locking (NEMA L5-30R): This outlet
can supply electrical power for operation of 120 Volt
output up to 30 amps.
10. Ground Terminal: The ground terminal is used to
ground the generator.
11. 120V AC, 20A, Single Phase, 60 Hz Outlet
(NEMA 5-20R): Outlet is capable of carrying
a maximum of 20 Amp.
12. Recoil Starter: Pull the recoil starter to manually start
the engine.
7
8

Publicidad

loading