Descargar Imprimir esta página

Gaggenau VG 491 211 Instrucciones De Instalación página 9

Ocultar thumbs Ver también para VG 491 211:

Publicidad

Idiomas disponibles

Idiomas disponibles

Special accessories
You can order the following accessories from your
specialist dealer:
AA 414 010
Ventilation molding, for operation
next to the VL 414 downdraft
ventilation
VA 420 000
Connection strip for combination
with other Vario appliances in the
400 series for flush installation
VA 420 010
Connection strip for combination
with other Vario appliances in the
400 series for surface-mounted
installation
Use the accessories only as indicated. The manufacturer
assumes no liability for incorrect usage of the
accessories.
Cabinet Requirements
The minimum spaces that must be maintained when
installing the gas cooktop shall be:
A
minimum 12" (300 mm)
B
minimum 12" (300 mm)
C
minimum 30" (762 mm) clearance between
the top of the cooking surface and the
bottom of combustible constructions
D
minimum 4" (102 mm)
for non-combustible back-walls the
minimum distance can be reduced to 1
(40 mm)
E
minimum 36" (914 mm)
F
minimum 18" (457 mm)
G
maximum 13" (330 mm)
The distance from the top of the cooktop to the bottom of
cabinets above can be reduced to 26" when the bottom of
the wood or metal cabinet is protected by not less than
¼" (6.35 mm)-thick flame-retardant millboard covered
with not less than No. 28 MSG sheet metal, 0.015 inch
(0.4 mm) stainless steel, 0.024 inch (0.6 mm) aluminum
or copper.
Countertop Requirements
9
WARNING
To reduce the risk of ignition of surrounding
combustible materials, install at least 12" (300 mm)
from both sidewalls and at least 4" (102 mm) from
the rear wall.
The countertop must be level and horizontal. The stability
of the countertop must be maintained after the cut-out
has been made.
Solid surface countertops often require special
installations. For example, heat-reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to your
countertop.
Technical Data
Total connected load electric
Total connected load gas
(natural gas)
Total consumption
(natural gas)
Total connected load gas
(propane gas)
Total consumption
(propane gas)
9
/
"
16
en-us
Before You Begin
25 VA
59,800 BTU/h
(17.5 kW)
1.6 m³/h
58,000 BTU/h
(17.0 kW)
1,210 g/h
9