Descargar Imprimir esta página

Sony VPL-FX51 Manual De Instrucciones página 31

Ocultar thumbs Ver también para VPL-FX51:

Publicidad

Idiomas disponibles

Idiomas disponibles

Notes
• Be sure to use the LMP-F300 Projector Lamp for
replacement. If you use lamps other than LMP-F300,
the projector may cause a malfunction.
• Be sure to turn off the projector and unplug the
power cord before replacing the lamp.
• Do not put your hands into the lamp replacement
spot, or not fall any liquid or object into it to avoid
electrical shock or fire.
Disposal of the used lamp
As the used lamp contains Mercury, dispose of the
lamp according to local, state or federal laws.
As the materials used in this lamp are similar to those
of a fluorescent lamp, you should dispose of a used
projector lamp in the same way as a fluorescent lamp.
Cleaning the Air Filter
When replacing the lamp, also clean the filter to
ensure optimal performance. When it becomes
difficult to remove the dust from the filter, replace the
filter with a new one.
To clean the air filter, follow the steps below:
1
Turn off the power and unplug the power cord.
2
Raise the side of the projector, and pull out the air
filter.
3
Remove the dust from the filter with a vacuum
cleaner.
4
Insert the air filter all the way in utnil it is securely
in place.
Notes
• If you neglect the air filter, dust may accumulate,
clogging it. As a result, the temperature may rise
inside the unit, leading to a possible malfunction or
fire.
• Be sure to insert the air filter firmly; the power will
not be turned on if it is not closed securely.
Maintenance
31
(GB)

Publicidad

loading