Descargar Imprimir esta página

Futurelight LCC-18 W/A Manual Del Usuario página 24

Publicidad

Idiomas disponibles

Idiomas disponibles

Control-channel - Strobe
Decimal Hexad. Percentage S/F
0 0
00 00
0% 0%
1 95
01 5F
0% 37%
96 127
60 7F
38% 50%
128 159
80 9F
50% 62%
160 191
A0 BF
63% 75%
192 223 C0 DF
75% 87%
224 255
E0 FF
88% 100%
Control-channel - Dimmer intensity
Only available, if control channel Internal Programs is not active.
Decimal Hexad. Percentage S/F
0 255
00 FF
0% 100%
DMX-512 connection / connection between fixtures
The wires must not come into contact with each other, otherwise
Please note, the starting address depends upon which controller is being used.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
S Open
F Strobe-effect with increasing speed
S Open
F Pulse-effect in sequences
S Open
F Random strobe-effect with increasing speed
S Open
F Gradual adjustment of the dimmer intensity from 0 to 100 %
the fixtures will not work at all, or will not work properly.