3. SPECIFICATIONS

Range:
Accuracy:
Cable Types:
Faults Indicated:
Fault Location:
Wiring Schemes:
Service Indication:
Voltage Warning:
Test Inhibit:
Tone Generator:
Battery indicator:
Main Unit Display:
Fault Display:
Display Backlight:
Remote Display:
Languages:
Power Supply:
Auto Power Off:
Battery Life:
Storage Temperature:
Operating Temperature:
Main Unit Weight:
Main Unit Dimensions:
Remote Weight:
30
500 ft (150m)
±5%
UTP, STP , FTP & SSTP
Short Circuit Pair
Open Circuit Wire
Short Between Pairs
Split / Cross Pairs
Pair Reversals
Shield Continuity
Near End, Remote End, or distance
if midway
TIA 568A/B, USOC & ISDN
Telephone, 10BaseT, 100Mbit+,
Token Ring
Warns of TNV (Telecom Network
Voltage) presence
Inhibits Testing in the presence of
live voltages
Tone generator (oscillating) 810Hz - 1110Hz
0 to 100% "Gas Gauge" Bargraph
128 x 64 pixel Graphical LCD
All fault and setting info displayed
textually and graphically
Electroluminescent
Green/Red LED
English (USA and UK), German,
French, Spanish, Italian
4 x 1.5V AA alkaline batteries
after 3 minutes
Standby mode >4000hrs
Continuous testing >7.5hrs
-4 to 158°F (-20 to 70°C)
5 to 95% RH non-condensing
32 to 112°F (0 to 40°C)
5 to 95% RH non-condensing
12 oz (350g)
6.5 x 3.5 x 1.5" (165 x 90 x 37mm)
1.5 oz (40g)
Remote Dimensions:
Safety:
EMC:
CE:
ESD:
EM:
Burst:
Conducted RF:
31
2.5 x 2.0 x 1.0" (65 x 52 x 25mm)
IEC61010-1
EN61326-1
Compliant with current EU directives
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-6