CODE
POSSIBLE CAUSE
27
Seized pump
28
Oil level too high
29
Poor ventilation
Dirty cooling surfaces
30
31
Too much back pressure in tank.
Compressor too cold
32
GLOSSARY
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air
delivery.
PSI: Pounds per square inch; a unit of measure of pressure.
Cut-in pressure: Factory set low pressure point that starts the
compressor to repressurize the tank to a higher pressure.
Cut-out pressure: Factory set high pressure point that stops
the compressor from increasing the pressure in the tank above a
certain level.
Well-ventilated: A means of providing fresh air in exchange for
dangerous exhaust or vapors.
Dedicated circuit: An electrical circuit reserved for the exclusive
use of the air compressor.
ASME: American Society of Mechanical Engineers. Indicates that
POSSIBLE SOLUTION
Contact a D
WALT factory service center or a D
e
service center.
Reduce to proper level. See Compressor Pump Oil under
Maintenance.
Relocate compressor to an area with cool, dry, well circulated
air, at least 12 in. from nearest wall.
Clean all cooling surfaces thoroughly.
Open drain valve when starting motor.
Move compressor to a warmer location.
the components are manufactured, tested and inspected to the
specifications set by ASME.
CSA: Canadian Standards Association
Indicates that the products that have this marking have
been manufactured, tested and inspected to standards
that are set by CSA.
Canadian Standards Association (USA): Indicates that the
products that have this marking have been
manufactured, tested and inspected to standards that
are set by CSA. These products also conform to U.L.
standard 1450.
California Code: Unit may comply with California Code 462 (l) (2)/
(M) (2). Specification/model label is on the side of the air tank on
units that comply with California Code.