Pressure does not build up in the
appliance
Check water supply for adequate deliv-
ery rate.
Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.
Appliance ventilation: Switch the appli-
ance on with the high-pressure hose
detached and operate (max. 2 minutes)
until the water exits the high-pressure
connection without bubbles. Switch off
appliance and reconnect high-pressure
hose.
Strong pressure fluctuations
Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.
Check water flow quantity.
Appliance is leaking
Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.
No detergent infeed
Detach spray lance from the trigger
gun. Work only with the trigger gun.
Clean the detergent suction hose filter.
Check the detergent suction hose for
kinks.
Accessories and Spare Parts
Only use original accessories and spare
parts, they ensure the safe and trouble-free
operation of the device.
For information about accessories and
spare parts, please visit www.kaerch-
er.com.
10
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch
Technical specifications
Electrical connection
Voltage
Connected load
Protection class
Protective class
Mains fuse (slow-blow)
Water connection
Max. feed pressure
Max. feed temperature
Min. feed volume
Performance data
Working pressure
Max. permissible pres-
sure
Water flow rate
Max. flow rate
Detergent flow rate
Recoil force of trigger
gun
Dimensions and weights
Length
Width
Height
Weight
Subject to technical changes.
– 10
EN
Warranty
220-240
1~50-60
1,2 kW
IP X5
10 A
1,2 MPa
40 °C
6,7 MPa
10 MPa
4,5 l/min
5,0 l/min
0,3 l/min
160 mm
241 mm
426 mm
5,8 kg
V
Hz
II
7 l/min
9 N