LD 15-10 125 R / LD 15-10 125 / LDE 15-10 125 R
Noise and Vibration
The noise and vibration values have been
determined in accordance with EN 60745.
The A evaluated noise level of the power
tool is typically:
– Sound pressure level:
– Sound power level:
– Uncertainty:
Total vibration value (when
sanding concrete areas):
– Emission value:
– Uncertainty:
Attention
The indicated measurements refer to new
power tools. Daily use causes the noise and
vibration values to change.
NOTE
The vibration emission level given in this
information sheet has been measured in
accordance with a standardised test given
in EN 60745 and may be used to compare
one tool with another. It may be used for
a preliminary assessment of exposure.
The declared vibration emission level
represents the main applications of the tool.
Technical specifications
Machine type
Mains voltage
Protection class
Power input
Speed
Rated speed
Tool holder
Max. disc diameter
Weight (without power
cord)
87.3 dB(A);
98.3 dB(A);
K = 3 dB.
2
a
= 6.4 m/s
h
2
K = 1.5 m/s
LD 15-10 125 R
V/Hz
W
r.p.m.
r.p.m.
mm
kg
2.9
However if the tool is used for different
applications, with different accessories or
poorly maintained, the vibration emission
may differ. This may significantly increase
the exposure level over the total working
period
For a precise estimation of the vibration load
the times should also be considered during
which the power tool is switched off or even
running, but not actually in use. This may
significantly increase the exposure level
over the total working period
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and the
accessories, keep the hands warm,
organisation of work patterns.
CAUTION!
Wear ear protection at a sound pressure
above 85 dB(A).
LD 15-10 125 LDE 15-10 125 R
Renovation sander
230/50
II /
1,450
10,000
11,700
M14
125
3.2
4,000-10,000
2.9
17