Descargar Imprimir esta página

ims PRO 25 K Manual De Instrucciones página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
POWER SUPPLY – STARTING UP
PLASMA CUTTER is supplied with a 16 A plug, type CEE7/7. Such 16A is suffcient for most of applications. However, for an optimal use of this cutting
machine, it can be necessary to replace this 16 A plug by a 25 A model.
They are power supplied by a 230V +/- 15% (50 - 60 Hz) EARTHED installation and are protected to work with generators. This hardware must only
be used with a one phase electricity supply protected by a earthing wire.
The absorbed effective current (I1eff) is displayed on the machine, for optimal use. Check that the power supply and its protection (fuse and/or circuit
breaker) are compatible with the current needed by the machine.
CONNECTION ON A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements :
- The voltage must be AC, always set as specified, and the peak voltage below 400V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as several generators generate high voltage peaks that can damage these
machines.
USE WITH EXTENSION CABLES
All extension cables must have an adequate size and section, relative to the machine's voltage.
Use an extension that complies with national safety regulations.
AIR SUPPLY (30FV)
The air supply can come from a compressor or high pressure bottles. A high pressure manometer must be used on any type of air supply and must be
able to transport the gas to the plasma cutter. These machines come with an integrated air filter (5 μm), but an extra filtering system can be necessary
depending on the quality of the air supply (impurities filter in option, ref. 039728).
If the supplied air is of low quality, the cutting speed is reduced, the cutting quality deteriorates, the maximum cutting capacity
diminishes and the life cycle of the consumables is reduced.
For optimal performance, the compressed air must comply with the standard ISO8573-1, class 1.2.2. The maximum vapor pressure point must be - 40
°C. The maximum oil quantity (aerosol, liquid et vapor) must be 0.1 mg/m3.
The recommended entry pressure during air circulation is 5 to 9 bars with a minimum of 115 L/min.
TORCH SETUP
The torches are cooled with ambient air and do not require any special cooling.
1 - CONSUMABLES LIFE CYCLE
The replacement frequency of the Plasma's consumables depends on several factors:
• The metal thickness.
• The average cutting time
• The air quality (presence of oil, humidity or other contaminants).
• The metal piercing or the cut from the edge.
• The adequate distance between the torch and the part when cutting.
In normal conditions :
- During manual cutting, the electrode wears out first.
18
PLASMA CUTTER 25 K / 35 KF / 30 FV
Voltage input
230 V
Section of extension cable (<45m)
6 mm²
Connecting the gas supply to the current source by means of an inert gas
pipe of an internal diameter of 9.5 mm and a quick connect coupler.
The pressure must not exceed 9 bars,
The filter's cuve could explose.
EN

Publicidad

loading

Este manual también es adecuado para:

35 kf30 fv