Prior to installation
For optimum extractor hood efficiency:
Short, smooth air exhaust pipe.
As few bends in the pipe as possible.
Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
Round pipes:
We recommend
Internal diameter: 150 mm (at least
120 mm).
Flat ducts must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
l 120 mm approx. 113 cm
l 150 mm approx. 177 cm
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that
there is an adequate supply of fresh air.
Recirculating mode
(If there is no possibility of operating in
exhaust-air mode)
The air drawn in by the extractor hood is
cleaned by an additional activated
carbon filter and then blown back into
the kitchen.
150
Connecting a l 150 mm exhaust-air
pipe:
Connecting a l 120 mm exhaust-air
pipe:
2
2
850
Mount the pipe directly onto the air
outlet on the hood.
Screw a reducing adapter onto the air
outlet on the hood and then connect the
exhaust-air pipe
90
16
910
25