Descargar Imprimir esta página

GYS GYSFLASH 8.12 PL Manual De Instrucciones página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Operating manual
Charging current:
1A
4A
8A
Selection designed to choose the most suited charging current based on the type and size of the battery
(lead-acid or lithium).
Charging current
Battery capacity
*Lead-acid battery equivalent : Lithium batteries have better starting performance (CCA) than lead-acid batteries. This is why some
lithium battery manufacturers indicate the lead battery equivalent (EqPb) corresponding to the capacity of a lead-acid battery with
the same starting performance. For instance, a 10Ah LFP battery will have approximately the same starting performance as a 30 Ah
lead-acid battery.
• Lead-acid charge curve:
The Gysflash 8.12 PL uses an advanced 7-step lead-acid charging curve that ensures optimal performance of your lead-acid battery.
1
U
I
Analyse
Récupération
< 1s
CHARGE
OK
1
Step
: Analysis
Analysis of the battery status (level of charge, reverse pola-
rity, incorrect battery connected...)
2
Step
: Recovery (0.5A - 3A)
Recovering damaged elements following a prolonged deep
discharge.
3
Step
: Test
Sulfated battery test
4
Step
: Desulphation (15.8V)
Battery desulphation process.
Translation of the original
instructions
1 A
Pb
15
LFP
2
3
4
Test
Désulfatation
max 8h
< 1s
max 12h
4 A
50Ah
-
-
1.2
20Ah
(36
60Ah EqPb*)
5
Charge
Absorption
max 25h
5
Step
: Charge (1A - 8A)
Fast charge at maximum current to reach 80% charge level.
6
Step
: Absorption (14.4V or 14.7V with AGM option)
Constant voltage load to bring the charge level to 100%.
7
Step
: Maintenance charge (13.6 V)
Maintaining the battery charge level at maximum.
GYSFLASH 8.12 PL
8 A
50
160Ah
20
160Ah
(60
480Ah EqPb*)
6
7
Maintien de
charge
max 8h
no limit
11

Publicidad

loading