3.3. ENVIRONMENTAL CONDITIONS
Operating range:
-10°C at 55°C and ≤ 80%RH without condensation up to
40°C.
Storage range (without battery):
-20°C at +55°C and ≤ 90%RH without condensation up to
45°C.
If an extended period of non-use is anticipated, or for storage,
withdraw the batteries from the housing.
For use indoors and outdoors without rain.
Pollution degree: 2.
Altitude: <2000m.
3.4. POWER SUPPLY
The instrument is powered by two 1.5V alkaline batteries
(type AAA or LR3).
Battery life is 100 h.
3.5. CHARACTERISTICS OF CONSTRUCTION
C.A 757
Dimensions (L x l x P) 180 x 52 x 45 mm
Mass
Cable
Protection rating
Drop test
MiniFlex sensor
Clamping diameter
Length of the sensor
Length of the connecting cable 1m, terminated by a specific
Mass
Protection rating
3.6. ELECTRICAL SAFETY
Electrical safety 600 V CAT III per IEC 61010-1, IEC 61010-
031, IEC 61010-032 and IEC 61010-2-033.
3.7. ELECTROMAGNETIC COMPATIBILITY
Emission and immunity in industrial environment according
to IEC 61326-1.
200 g approx.
length 142 cm
IP 54 according to IEC 60529
IK 04 according to IEC 50102
2 m.
70 mm
250 mm
three-point plug
6,0 g approx.
IP 50 according to IEC 60529
IK 04 according to IEC 50102