Fault
Low water temperature
Seat is not warm
Dryer air is not warm
9 Technical Data
9.1 General Data
Power supply
Max. power consumption
Intermittent (periodic
operation)
Type of protection, entire
device
Length of power cord
Battery type remote control
Type water supply
connection
Ø Connection at shower
toilet
Ø T-piece
Ø Connection hose
Length connection hose
Water supply pressure
Water supply temperature
Operating temperature
Product width
Product length
Product depth
Product weight
Cleansing Functions
Water flow rate CLEANSING
Water flow rate BIDET
Water pressure adjustment
Temperature adjustment
Heater capacity
Safety devices
1590625-G
Possible cause(s)
Nozzle head is dirty
The water temperature level is turned
off or set to "LOW"
The warm seat temperature level is
turned off or set to "LOW"
The warm air dryer temperature level is
turned off or set to "LOW"
220 – 240 V AC, 50/60 Hz
1725 – 2053 W
85%, 30 min. ON /
5 min. OFF
IPX4
1)
1.4 m
2 x AA (LR6) / 1.5 V
Direct connection to the
water supply
1/2"
1/2"- 3/8" - 1/2"
1/2" cranked to 3/8"
500 mm
79 – 735 kPa
3 – 25 °C
3 – 40 °C
389 mm
515 mm
156 mm
3.9 kg
0.7 l/min
0.85 l/min
3 levels
Normal water supply
temperature,
34 °C, 37 °C, 40 °C
1670 – 1987 W
Thermal fuse, Thermostat
Remedy
Clean nozzle, → Cleaning Instructions,
page 9 .
Turn on or increase water temperature
level,
→ 5.4 Using the Shower Toilet, page 7 .
Turn on or increase seat temperature
level,
→ 5.4 Using the Shower Toilet, page 7 .
Turn on or increase warm air dryer
temperature level,
→ 5.4 Using the Shower Toilet, page 7 .
Warm Seat
Temperature adjustment
Heater capacity
Safety devices
Drying Functions
Temperature adjustment
Heater capacity
Safety devices
1)
Protected against the penetration of water that is splashed
against the housing from all directions (warm seat only).
9.2 Materials
Seat / Lid
All product components are corrosion resistant and do not
contain natural rubber latex.
9.3 Environmental Parameters
Operating conditions
Ambient temperature
Relative humidity
Atmospheric pressure
Storage and shipping conditions
Ambient temperature
Relative humidity
Atmospheric pressure
Room temperature,
35 °C, 38 °C, 40 °C
55 – 65 W
Thermal fuse
Room temperature –
50 °C (5 levels)
195 – 232 W
Thermal fuse, Bi-metal
PP
3 - 40 °C
15 % - 93 %, non-condensing
795 - 1060 hPa
0 - 40 °C
30 % - 75 %, non-condensing
795 - 1060 hPa